Appendix
A.4 Index of the status bytes
Hexadecimal
value
0x80
0x81
0x82
0x83
0x84
Hexadecimal
value
0x92
0x93
106
Interface status
Unknown command:
Selected function not supported by reader
Length error:
Selected function has the wrong number of parameters
Command is not possible:
The reader is in the wrong mode.
Command is not supported
RF communication error:
This error indicates that there is an error in the communication between the
transponder and the reader. Possible reasons for this:
The algorithm for collision handling was not continued until no more collisions
were detected. Reason for interruption:
TR-RESPONSE-TIME in CFG1: COM interface is too short
Transponder is in the borderline read area
Too much noise in the antenna field
RF error:
You can read detailed status information with the "[0x6E] Reader Diagnostic
(Page 53)" command.
Check for incorrect configuration of the antenna, antenna cable and antenna
setting.
Ambient noise too high
RF power does not match the configured value
Temperature of the RF end-stage too high, RF power can be reduce or be
turned off completely.
Defective RF hardware
Buffer status
no valid data:
No valid data in the Buffered Read Mode
No transponder in the antenna field
VALID-TIME in the "CFG11: Read mode - read data (Page 31)" command for
the transponders in the antenna field has not yet elapsed
Data buffer overflow:
The data buffer has overflowed
Configuration Manual, 09/2014, C79000-G8976-C377-01
RF290R