Name
Description
OUTPUT-
Specifies the number of output channels used for multiplexing.
CHAN-
Function
NELS
OUTPUT-
CHAN-
NELS
MUX-
As soon as this time has expired (value x 5 ms), the next antenna output is selected.
VALID-
If "no response" is selected for the MUX switching condition, the reader switches from the active antenna to
TIME-ANT
the next antenna if there is no response from any transponder of the active antenna. If the transponder com-
munication time of the active antenna exceeds MUX-VALID-TIME-ANT, the transponder communication of the
active antenna is stopped and the reader switches to the next antenna. If "fixed" is selected as the switching
condition, the switch to the next channel is always within this period.
INPUT-
Specifies the number of inputs
CHAN-
Function
NELS
INPUT-
CHAN-
NELS
5.14
CFG16: Reset persistency
The parameters in CFG16 are used to configure the reader reset times for the persistence
flags of the transponders. The times for resetting the persistence flags are used by the
reader in the ISO host mode, "Scan Mode" and "Buffered Read Mode".
Byte
0
Content
0x00
Default
-
Byte
7
Content
0x00
Default
-
RF290R
Configuration Manual, 09/2014, C79000-G8976-C377-01
Description
b001
1 antenna
b010
2 antennas
b011
3 antennas
b100
4 antennas
b101
5 antennas
b110
6 antennas
Description
b00 -
b01 1 input
b10 reserved
1
0x00
PER-RESET-TIME
-
40 x 5 ms = 200 ms
8
0x00
0x00
-
2
3
0x0028
9
10
0x00
-
-
Configuration parameters (CFG)
5.14 CFG16: Reset persistency
4
5
0x00
0x00
-
-
11
12
0x00
0x00
-
-
6
0x00
-
13
0x00
-