Data transmission between RF290R and host
3.2 ISO 15693 host commands
Figure 3-6
Selected mode
In this mode, the reader communicates only with the one selected transponder.
Before data can be read or written in the selected mode, the UID of the transponder must be
known. You can obtain the UID by sending the command "[0x01] Inventory". In a second
step, the transponder must be selected with the command "[0x25] Select". This must include
the UID of the transponder.
The following graphics show the necessary steps for communication with a transponder in
the selected mode.
Figure 3-7
14
Sequence when writing in the non-addressed mode
Sequence when calling up the UID in the selected mode