ISO 15693 host commands
9.2 Supported ISO 15693 host command for ISO 15693 transponders
Command code Function
-
-
0x01
Inventory
0x02
Stay Quiet
0x22
Lock Multiple
Blocks
0x23
Read Multiple
Blocks
0x24
Write Multiple
Blocks
0x25
Select
0x26
Reset to Ready ✓
0x27
Write AFI
0x28
Lock AFI
0x29
Write DSFID
0x2A
Lock DSFID
0x2B
Get System
Information
0x2C
Get Multiple
Block Security
Status
1) The WR-OPTION is set automatically by the reader if the WR-OPTION parameter in the "CFG4 transponder parameters"
is set to "00: specified automatically". With one request, up to two blocks can be written with data.
2) Reading a block in non-addressed mode is only possible if the "Read mode" parameter in the "CFG4 transponder pa-
rameters" is set to "b01: read once".
9.2.11
NXP (I-Code SLIX)
Chip ID: 2h = 00000001b (bits 47 - 40 of UID)
Table 9- 17
Number of blocks
Block size
Number of pages
Page size
88
Mode
not addressed
-
-
2)
-
-
-
Memory arrangement 32 × 4 bytes = 1280 bits
addresses
Selection
-
-
-
-
-
-
28 (user range: 0 ... 27)
4 bytes
10 (user range: 0 ... 9)
16 bytes = 4 blocks
Configuration Manual, 09/2014, C79000-G8976-C377-01
Comment
-
-
-
WR-OPTION = 0
1)
DB-SIZE = 4
DB-SIZE = 4
WR-OPTION = 0
1)
-
-
WR-OPTION = 0
1)
WR-OPTION = 0
1)
WR-OPTION = 0
1)
WR-OPTION = 0
1)
-
-
RF290R