ISO 15693 host commands
9.2 Supported ISO 15693 host command for ISO 15693 transponders
Command code Function
0x28
Lock AFI
0x29
Write DSFID
0x2A
Lock DSFID
0x2B
Get System
Information
0x2C
Get Multiple
Block Security
Status
1) The WR-OPTION is set automatically by the reader if the WR-OPTION parameter in the "CFG4 transponder parameters"
is set to "00: specified automatically". With one request, up to two blocks can be written with data.
2) The user-specific Read Multiple Blocks Unlimited [0xA3] commands are used automatically by the reader. In the non-
addressed mode, only one or two blocks can be read and the DB block size parameter in the "CFG4 transponder pa-
rameters" must be set to 8.
9.2.4
Fujitsu (MB89R118)
IC manufacturer identifier: 0x08
Chip ID: 1h = 00000001b (bit 47 - 40 of UID)
Table 9- 9
Number of blocks
Block size
Command code Function
-
-
0x01
Inventory
0x02
Stay Quiet
0x22
Lock Multiple
Blocks
0x23
Read Multiple
Blocks
2)
0x24
Write Multiple
Blocks
1)
0x25
Select
0x26
Reset to Ready ✓
0x27
Write AFI
0x28
Lock AFI
0x29
Write DSFID
0x2A
Lock DSFID
82
Mode
Memory arrangement 256 × 8 bytes = 16 Kbits
Mode
not addressed
-
-
-
256 (user range: 0 ... 249)
8 bytes
addresses
Selection
-
-
-
-
Configuration Manual, 09/2014, C79000-G8976-C377-01
Comment
WR-OPTION = 0
or 1
-
-
-
-
Comment
-
-
-
WR-OPTION = 0
or 1
Security status is
always 0x00
WR-OPTION = 0
or 1
-
-
WR-OPTION = 0
or 1
WR-OPTION = 0
or 1
-
-