Download Print this page

Siemens SIMATIC RF290R Configuration Manual page 61

Advertisement

Protocols for ISO 15693 host commands
8.1
[0xB0] Host commands for mandatory commands according to ISO
15693 and optional commands
This command sends RF commands defined according to ISO 15693 to the transponder.
Table 8- 1
Host → reader
Byte
1
Content
STX
Default
0x02
Table 8- 2
Reader → host
Byte
1
Content
STX
Default
0x02
You will find further information in the Appendix (Page 103).
1)
Name
REQUEST-
DATA
RESPONSE-
DATA
Note
Restrictions
Data is only transferred if STATUS = {0x00, 0x83, 0x84, 0x93, 0x94, 0x95}.
The command does not work if Buffered Read Mode or Scan Mode is activated.
8.2
[0x01] Inventory
This command reads the UIDs of all transponders in the antenna field.
If the reader has identified a new transponder, it automatically sets this to the quiet state. In
this state, the transponder does not send a reply to the next inventory command.
RF290R
Configuration Manual, 09/2014, C79000-G8976-C377-01
2
3
MSB
LSB
ALENGTH
ALENGTH
-
-
2
3
MSB
LSB
ALENGTH
ALENGTH
-
-
Description
Command-specific request
Command-specific response
4
COM-ADR
[0xB0]
-
4
5
COM-ADR
[0xB0]
-
-
5
6 ... n-2
REQUEST-
DATA
-
-
6
7 ... n-2
STATUS
RESPONS
1)
E-DATA
-
-
8
n -1, n
CRC16
-
n-1, n
CRC16
-
61

Advertisement

loading