Download Print this page

Siemens SIMATIC RF290R Configuration Manual page 58

Advertisement

Protocols for controlling the reader
7.12 [0x86] Get System Timer
Table 7- 26
Reader → host
Byte
1
Content
STX
Default
0x02
You will find further information in the Appendix (Page 103).
1)
Name
Description
TIMER
Byte
TIME
Value
Note
Internal system time
The internal system time is not a real-time clock (RTC) and the accuracy cannot be
guaranteed.
58
2
3
MSB
LSB
ALENGTH
ALENGTH
-
-
7
h
0 ... 23
4
5
COM-ADR
[0x86]
-
-
8
min
0 ... 59
Configuration Manual, 09/2014, C79000-G8976-C377-01
6
7 ... 10
STATUS
TIMER
1)
-
-
9, 10
ms
0 ... 59999
11, 12
CRC16
-
RF290R