Siemens SIMATIC RF290R Configuration Manual page 34

Advertisement

Configuration parameters (CFG)
5.10 CFG12: Read mode - filter
You will find further information on valid addresses and data block sizes in the section
1)
"Supported ISO 15693 host command for ISO 15693 transponders (Page 79)".
5.10
CFG12: Read mode - filter
Byte
0
Content
VALID-TIME
Default
0x0037
Byte
7
Content
0x00
Default
-
Name
Description
VALID-
The period during which a transponder cannot be read a second time.
TIME
0...65535 x 100 ms = 0 ms ... 6553.5 s
Note:
A change to VALID-TIME only takes effect after configuration block CFG12 has been written to the EEPROM
and the CPU has been reset.
TR-ID
TR-ID specifies the parameters for the transponder identification. If several transponders have the same con-
tent in the addressed data block, only one data set is generated.
This function is available only in "Buffered Read Mode".
Byte
Function
Function
TR-ID-
SOURCE
TR-ID-DB-
ADR
TR-ID-DB-N Specifies the number of data blocks to be read for the transponder identification. If the serial
34
1
5,5 s
8
0x00
0x00
-
2
TR-ID-SOURCE
Description
Specifies the data source for the transponder identification.
b0 data block
b1 serial number
Specifies the address of the data block for the transponder identification. If the serial number is
selected as the data source in ID-SOURCE, ID-DB-ADR is ignored.
number is selected as the data source in "TR-ID-SOURCE", "TR-ID-DB-N" is ignored.
2
3
TR-ID
0x01000001
9
10
0x00
-
-
3
TR-ID-DB-ADR
Configuration Manual, 09/2014, C79000-G8976-C377-01
4
5
11
12
0x00
0x00
-
-
4
TR-ID-DB-N
6
0x00
-
13
0x00
-
5
RF290R