Current Mode View - Kemppi MasterTig 535ACDC Operating Manual

Table of Contents

Advertisement

3.2.6 Current mode view

To adjust parameters:
1.
Go to the Current mode view.
2.
Turn the control knob (1) to browse through the parameters.
3.
Select a parameter to be adjusted by pressing the control knob (1).
4.
Adjust the parameter by turning the control knob (1).
5.
Close the parameter setting by pressing the control knob (1).
Adjustable parameters:
Parameter
Current mode
AC Waveform
AC Frequency
AC+ / AC- balance
MIX TIG AC ratio
MIX TIG cycle time
MIX TIG DC level
© Kemppi
Value
DC- / DC+ / AC / MIX
Square / Optima / Sine (Default = Optima)
30 Hz ... 250 Hz, step 1.0 Hz
Min/Max = -60 % ... 0 %, step 1 % (Default = -25%)
Min/Max = 10 % ... 90 %, step 1 % (Default = 50 %)
Min/Max = 0.1 s ... 1.0 s, step 0.1 s (Default = 0.6 s)
Min/Max = 50 % ... 150 %, step 1 % (Default = 100 %)
43
MasterTig 535ACDC
Operating manual - EN
1921940 / 2140

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mastertig cooler mxl535acdcg m

Table of Contents