Cooling Unit Mastertig Cooler Mxl - Kemppi MasterTig 535ACDC Operating Manual

Table of Contents

Advertisement

5.2 Cooling unit MasterTig Cooler MXL

MASTERTIG COOLER MXL
Feature
Connection voltage
Maximum rated supply current
Rated cooling power at 1 l/min
Cooling power at 1 l/min
Recommended coolant
Coolant pressure (max)
Tank volume
Operating temperature range *
Storage temperature range
EMC class
Degree of protection **
External dimensions
Weight without accessories
Standards
* With recommended coolant
** When mounted
© Kemppi
Description
Value
U
50/60 Hz
220...460 V AC, 1~/3~
1
I
1.0 A
1max
1.7 kW
1.7 kW
MPG 4456 (Kemppi mixture)
0.4 MPa
3.0 l
-20 ... +40 °C
-20 ... +60 °C
A
IP23S
L x W x H
825 x 276 x 289 mm
25 kg
IEC 60974-2, -10
60
MasterTig 535ACDC
Operating manual - EN
1921940 / 2140

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mastertig cooler mxl535acdcg m

Table of Contents