3.3.5 Current mode view
To adjust parameters:
1.
Go to the Current mode view.
2.
Turn the control knob (1) to browse through the parameters.
3.
Select a parameter to be adjusted by pressing the control knob (1).
4.
Adjust the parameter by turning the control knob (1).
5.
Close the parameter setting by pressing the control knob (1).
Adjustable parameters:
Current mode: DC- / DC+ / AC / MIX
AC Waveform: Sine / Optima / Square (Default: Optima)
AC Frequency: 30 Hz ... 250 Hz (Default = 60 Hz)
AC+ / AC- balance: Min/Max = -60 % ... 0 % (Default = -25%)
MIX TIG AC (time) ratio: Min/Max = 10 % ... 90 %, step 1 % (Default = 50 %)
MIX TIG cycle time: Min/Max = 0.1 s ... 1.0 s, step 0.1 s (Default = 0.6 s)
MIX TIG DC level: Min/Max = 50 % ... 150 %, step 1 % (Default = 100 %).
© Kemppi
MasterTig 235ACDC, 325DC, 335ACDC
43/73
Operating manual - EN