Basic Setup

Neo450 UPS Information

Supplying power to the Neo450 via a suitable UPS offers two advantages:
Maintaining operation during a short power outage
Additional power supply quality protection
When connected to a Stratasys certified UPS, the system will benefit intelligent UPS control
functionality. Intelligent UPS control offers further advantages:
Controlled shutdown
Uncontrolled system shutdowns pose a risk of damage to electronic components. In the
event of an power outage, the remaining up-time is monitored and the system will initiate a
controlled shut down before the UPS is unable to maintain supply.
Minimal UPS capacity requirement
In the event of a power outage non-critical vat heating is suspended to minimise the UPS
capacity specification requirement.
Ensures build restart
Titanium is often able to recover and restart a build following an uncontrolled shut down,
however this is not guaranteed due to the nature of the event. A controlled shut down
ensures a build restart is possible when the power is resumed.
UPS status monitoring
The UPS is continuously monitored by Titanium. UPS faults and health status are reported
in Titanium.
Europe, Israel, South Korea,
Russia
USA, Canada
*Not available in Colorado, Vermont or Washington State
A "Certified UPS" has been tested for communication compatibility. Alternative UPS brands
and models may be compatible if they offer serial communication using the SHUT Protocol.
Caution
For the highest system functionality and protection, Stratasys recommends the
Neo450 is supplied via an Stratasys certified UPS.
Table 11: Neo450 Certified UPS
© Copyright 2022 Stratasys. All rights reserved.
110 ~ 120 VAC
N/A
Eaton 5P1500*
Neo450 UPS Information
220 ~ 240 VAC
Eaton 5P1550i
N/A
Page 24