Environmental Requirements - Stratasys F120 Site Preparation Manual

Hide thumbs Also See for F120:
Table of Contents

Advertisement

Site Preparation Guide

Environmental Requirements

The F120 printer can be used in any controlled environment.
Air quality conditions with excessive solid particulates (conductive or non-conductive) may
result in system damage.
Air quality conditions in which airborne oils are allowed to accumulate on or within the
printer can damage the plastic components.
System operating temperature shall be in the range of 59°F to 86°F (15°C to 30°C), with
relative humidity range of 30% to 70% non-condensing.
System storage temperature shall be in the range of 32°F to 95°F (0°C to 35°C), with
relative humidity range of 20% to 90% non-condensing.
Altitude shall not exceed 6561.68 feet (2000 m).
Material storage shall be in the range of 55°F to 86°F (13°C to 30°C), with relative humidity
less than 70%.
Noise emission (acoustic):
Heat Output
Heat dissipation occurs mostly through the top of the printer. Heat output is material dependent
due to the various temperatures maintained in the build chamber.
ABS
ASA
Power Consumption
Power consumption is material dependent due to the various temperatures maintained in the
build chamber.
ABS
ASA
<32dBA when idle
<46dBA when building
Material Type
~2300 BTU/hr
~2300 BTU/hr
Material Type
Consumption
(while building)
650 W
650 W
Heat Output (while building)
Power
Power Consumption
510 W
510 W
Heat Output (while idle)
~1800 BTU/hr
~1800 BTU/hr
Consumption
(while idle)
(while sleeping)
10 W
10 W