For details on operation mode and function combinations, see "Basic Function Matrix" (page 19).

Image Output Timing

■ Trigger Control
The camera allows Line Start trigger controls to be performed via external trigger signals.
The Line Start trigger allows exposure control via the trigger signal inputs.
The settings for exposure control and triggers are related to each other. Be sure to configure the settings
described in "Connecting to the Camera to Control Tool" (page 14).
Shortest Repetition Period for Triggers
Trigger Mode ON, full resolution
Exposure Mode OFF
Exposure Mode Timed
PWC
Shortest Trigger Pulse Width
Trigger Mode ON
Exposure Mode OFF
Exposure Mode Timed
PWC
Camera Link
12-pin
Varies depending on the Tap
Camera Link
Geometry and CL Clock
12-pin
Camera Link
12-pin
Camera Link
3 µs
50 µs
3 µs
50 µs
3 µs
50 µs
— 21 —
Shortest period (µs)
settings.