Rounding:
Scale
Type:
Command Type:
Setting
Syntax:
Examples:
Considerations:
1) The start address and the length must meet the specification that. Start address + Length - 1
2) The 'scale' refers to the scaling of the waveform as a percentage of full scale. A scale of
SHAPE
SIN
SQU
TRI
NOIS
URAM
DRAM
SINX
EXPU
EXPD
GAUS
Start Address
:ARBitrary:STARt <start address>
This command sets the start address of the waveform to be run.
1.800.544.2843
DRAM: 16 to 65,536
NOIS: 16 to 65,536
ANO:
16 to 65,536
SINX: 16 to 65,536
EXPU: 16 to 65,536
EXPD: 16 to 65,536
GAUS: 16 to 65,536
to integer value
Numeric. MIN sets the scale to 1; MAX sets the scale to 100
Range:
Rounding;
Setting only
:ARBitrary:PREDefined<ws> <shape>, <start>, <length>,<scale>
:ARB:PRED SIN,1,1e3,100
:ARB:PRED URAM,1001,1e3,50
<= 16,777,216
100% will, under the correct conditions, generate a waveform whose data values range
from -8191 to +8191. These 'correct conditions' are set by the 'offset' value. This offset is
the value of the data at the start address, and determines the maximum scale settable. The
following table shows the data values required in order to achieve maximum scale.
DATA
0
0
0
0
-8191
+8191
0
-8191
+8191
0
www.calcert.com
15
10
20
5
25
0
30
1 to 100 (See considerations)
to integer value
77