Step 2: Load a 5% scaled, 100-point predefined
waveform into waveform memory starting at
address 200.
Step 3: Draw a line between address 251 (the
highest point of the sine wave) and address 501
(where the sine wave crosses the origin).
Step 4: Add a negative pulse/glitch (data value -
8191) at addresses 600 through 606.
Step 5: Add a 5% noise signal to addresses 700
through 800.
1.800.544.2843
31
www.calcert.com
15
10
20
5
25
0
30
F3: YES
F3: PREDEF
F1: TYPE
SINE
F2: FROM
200
F3: LENG
100
F4: SCAL
5
F5: EXEC
F3: YES
F2: LINE
F1: FROM
251
F2: TO
501
F4: EXEC
F3: YES
F1: POINT
F1: ADRS
600
F2: DATA
-8191
(repeat -8191 and ENTER
for addresses 601-606)
F5: PREV
F3:PREDEF
F2:FROM
700
F3:LENG
100
F4:SCAL
5
F1:TYPE
NOISE
F5:EXEC
F1:ADD
F4:EXEC
F3-YES