Step 7: Connecting To Port(S) On The Freedom; Step 8: Testing Your Installation - Xantrex Freedom X 1000 120VAC 12VDC Owner's Manual

Table of Contents

Advertisement

Step 7: Connecting to Port(s) on the
Freedom X
Connecting to the Remote Port
The Freedom X can accommodate the Freedom X Remote Panel
with cable (PN: 808-0817-01) (sold separately; comes with 25ft-
cable) or the Freedom X Remote Panel unit (PN: 808-0817) (sold
separately; unit only without cable).
To connect the remote panel to the remote port:
Plug the remote panel unit's cable connector to the RJ12
n
Remote port on the unit.
NOTE: When the remote panel is connected, turn the inverter's
power button to the Standby mode (up position). This allows the
remote panel to control the inverter's power status.
975-0787-01-01

Step 8: Testing Your Installation

ELECTRIC SHOCK HAZARD
Pressing the Power button to turn the Freedom X inverter to
Standby mode on the display panel does not disconnect DC or AC
input power to the Freedom X. If shore power is present at AC input
terminals, it will pass through to the AC output.
Failure to follow these instructions can result in death, serious
injury, or equipment damage.
There are two tests to be performed. The first test verifies that the
Freedom X is inverting DC battery power and delivering AC power
to its output.
The second test is intended for installations where AC input and
output is hard wired to the Freedom X. This test verifies that the
Freedom X transfers from inverter power to shore power when
shore power is present.
NOTE: Shore power (pass-through) refers to the AC input power
from a utility grid, generator or external AC source.
When you are ready to test your installation and operate the
Freedom X, close the DC fuse and Disconnect or the DC circuit
breaker to supply DC power to the Freedom X.
Basic Installation Procedures
WARNING
39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents