AirWorks AWK-1137C UM
First-time Installation and Configuration
Before installing the AWK-1137C, make sure that all items in the Package Checklist are in the box. You will need
access to a notebook computer or PC equipped with an Ethernet port. The AWK-1137C has a default IP address
that must be used when connecting to the device for the first time.
Step 1: Connect a power source.
•
The AWK-1137C can be powered by a DC power input.
•
Step 2: Connect the AWK-1137C to a notebook or PC.
Since the AWK-1137C supports MDI/MDI-X auto-sensing, you can use either a straight-through cable or
crossover cable to connect the AWK-1137C to a computer. The LED indicator on the AWK-1137C's LAN port
will light up when a connection is established.
•
Step 3: Set up the computer's IP address.
Choose an IP address on the same subnet as the AWK-1137C. Since the AWK-1137C's default IP address
is 192.168.127.253, and the subnet mask is 255.255.255.0, you should set the IP address of the
computer to 192.168.127.xxx.
After you select Maintenance Load Factory Default and click the Submit button, the AWK-1137C will be
NOTE
reset to factory default settings and the IP address will be reset to 192.168.127.253.
•
Step 4: Use the web-based manager to configure the AWK-1137C
Open your computer's web browser and type http://192.168.127.253 in the address field to access the
homepage of the web-based Network Manager. Before the homepage opens, you will need to enter the
Username and Password as shown in the following figure. For first-time configuration, enter the default
username and password and then click on the Login button.
2-2
Getting Started