AirWorks AWK-1137C UM
UDP Mode
UDP is similar to TCP but is faster and more
efficient. Data can be broadcast to or received
from multiple network hosts. However, UDP
does not support verification of data and would
not be suitable for applications where data
integrity is critical. It is ideal for message
display applications.
When Mode is set to UDP on a serial port's Operation Modes page, you will be able to configure additional
settings such as Destination address 1 through 4, Local listen port, and Packet length.
Destination Address 1 to 4
Setting
IP address range and
port (e.g.,
"192.168.1.1" to
"192.168.1.64" and
"4001")
Local Listen Port
Setting
0 to 9999
Description
In UDP mode, you may specify up to 4 ranges of IP addresses
for the serial port to connect to. At least one destination range
must be provided.
The maximum selectable IP address range is 64 addresses.
However, you can enter multicast addresses in the Begin field,
in the form xxx.xxx.xxx.255. For example, enter
"192.127.168.255" to allow the AWK-1137C to broadcast UDP
packets.
Description
This field specifies the UDP port that the AWK-1137C listens to
and that other devices must use to contact the attached serial
device.
3-42
Web Console Configuration
Factory Default
Begin: Empty
End: Empty
Port: 4001
Factory Default
4001