Moxa Technologies AirWorks AWK-1137C Series User Manual page 54

Hide thumbs Also See for AirWorks AWK-1137C Series:
Table of Contents

Advertisement

AirWorks AWK-1137C UM
Ignore Jammed IP
Setting
Disable
Enable
This field specifies how an unresponsive IP address is handled when there are simultaneous connections to the
serial port.
Destination Address 1 to 4
Setting
IP address and port
(e.g., "192.168.1.1"
and "4001")
ATTENTION
In TCP Client mode, up to 4 connections can be established between the serial port and TCP hosts. The
connection speed or throughput may be low if any one of the four connections is slow, since the one slow
connection will slow down the other 3 connections.
Designated Local Port 1 to 4
Setting
1 to 65535
Connection Control
This field specifies how connections to the device are established and closed.
Setting
Startup/None
Any Character/None
Any Character/
Inactivity Time
DCD On/DCD Off
DCD On/None
Packet Length
Setting
0 to 1024
Description
All transmission will be suspended if one IP address becomes
unresponsive. Transmission will only resume when all hosts
have responded.
Data transmission to the other hosts will not be suspended if
one IP address becomes unresponsive.
Description
This field specifies the remote host(s) that will access the
attached device. At least one destination must be provided.
This field supports the use of domain names and names defined
in the host table.
Description
This field specifies the TCP port number that will be used for
data transmission with the serial port.
Description
The connection will be opened as the AWK-1137C starts up.
The connection will only be closed manually.
The connection will be opened as soon as a character is
received from the attached device. The connection will only be
closed manually.
The connection will be opened as soon as a character is
received from the attached device. The connection will be
closed if no data is received for the time specified in Inactivity
time.
The TCP connection is opened when the DCD (data carrier
detect) signal is on, and closed when the DCD signal is off.
The TCP connection is opened when the DCD signal is on. The
connection will only be closed manually.
Description
This field specifies the maximum amount of data that is allowed
to accumulate in the serial port buffer before sending.
0: Packet length is disregarded and data in the buffer will be
sent as specified by the delimiter settings or when the buffer is
full.
1 to 1024: Data in the buffer will be sent as soon it reaches the
specified length.
3-40
Web Console Configuration
Factory Default
Disable
Factory Default
IP Address: Empty
Port: 4001
Factory Default
0
Factory Default
Startup/None
Factory Default
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Airworks awk-1137c-usAirworks awk-1137c-um

Table of Contents