Data Bits
Setting
5, 6, 7, 8
Stop Bits
Setting
1, 1.5, 2
Parity
Setting
None, Odd, Even,
Space, Mark
Flow Control
Setting
None, RTS/CTS,
XON/XOFF
FIFO
Setting
Enable, Disable
Interface
Setting
RS-232, RS-422,
RS-485 2-wire,
RS-485 4-wire
Data Buffering/Log
On the serial port's Data Buffering/Log page, you can enable or disable Port buffering and Serial data
logging.
Description
This field specifies the number of data bits used to encode each
character of data.
Description
This field specifies the number of stop bits used for each
character frame.
Description
This field specifies the type of parity bit used for each character
frame.
Description
This field specifies the type of flow control used by the serial
port.
Description
This field specifies whether the serial port will use the built-in
FIFO. A 128-byte FIFO is provided to each serial port for both
Tx and Rx directions. To prevent data loss during serial
communication, this should be set to Disable if the attached
serial device does not have a FIFO.
Description
This field specifies the type of interface the serial port will use. RS-232
3-45
Web Console Configuration
Factory Default
8
Factory Default
1
Factory Default
None
Factory Default
RTS/CTS
Factory Default
Disable
Factory Default