AirWorks AWK-1137C UM
NOTE
If the Password-strength test option is enabled, you will be prompted to use passwords that adhere to the
following password policy:
The password must contain at least one digit: 0, 1, 2, ..., 9.
•
•
The password must contain both upper and lower case letters:
A, B, ..., Z, a, b, ..., z.
•
The password must contain at least one of the following special characters:
~!@#$%^-_:,.<>[]{}
The password cannot contain the following special characters:
•
` ' " | ; &
The password must have more characters than the minimum password length (default = 4).
•
Miscellaneous Settings
Additional settings that help you manage your AWK-1137C are available on this page.
Select one of the following Reset button options:
•
Always enable–Set the reset button to perform a factory restore on the AWK-1137C. This is the default
option.
Disable factory reset function after 60 seconds–Deactivate the factory reset function of the reset
•
button 60 seconds after the AWK-1137C restarts.
Troubleshooting
This feature allows you to quickly obtain the current system status and provide diagnostics information to Moxa
engineers.
To export the current device information, click Export.
For cases where advanced troubleshooting is required, Moxa Service Center will send you an encrypted script
file. The script file can capture additional details on the system.
To run the script, browse to and select the script file using Browse and click Run Script after you have filled
in the following details:
3-72
Web Console Configuration