Setting

Communication Parameters

The Communication Parameters page for the serial port is where serial communication settings are
specified, such as Baud rate, Data bits, and Stop bits.
The Communication Parameters page for the serial port is where serial communication settings are
specified, such as Baud rate, Data bits, and Stop bits.
Port Alias
Setting
free text (e.g.,
"Secondary console
connection")
ATTENTION
Serial communication settings should match the attached serial device. Check the communication settings in
the user's manual for your serial device.
Baud Rate
Setting
75, 110, 134, 150, 300,
600, 1200, 1800, 2400,
4800, 7200, 9600,
19200, 38400, 57600,
115200, 230400,
460800, 921600
Description
than one character interval within the specified baudrate. For
example, assume that the serial port is set to 1200 bps, 8 data
bits, 1 stop bit, and no parity. In this case, the total number of
bits needed to send a character is 10 bits, and the time required
to transfer one character is 8.3 ms, so the force transmit time
to be larger than 8.3 ms.
Description
This is an optional free text field to help you differentiate one
serial port from another. It does not affect operation of the
AWK-1137C.
Description
This field specifies the baudrate for the serial port.
75 to 921600: The serial port will operate at the specified
baudrate.
3-44
Web Console Configuration
Factory Default
Factory Default
Factory Default
115200