en | Optional Modules and Peripheral Devices
Notice!
The maximum number of keypads to be added to one option bus is 8.
4.2.4

Status Indicator

If all indicators of the keypad are flashing, the keypad loses connection to the AMAX panel.
4.3

DX2010

4.3.1

General

The AMAX panel supports DX2010 input expansion modules. Each expansion module supports
up to 8 zone inputs.
For information on the installation, refer to Module Installation, page 26.
4.3.2

Address Setting

Each DX2010 module connected to the AMAX panel needs its own data bus address.
Data Bus Address
102***
103**
104**
105*
106*
107*
108*
Table 4.4: DX2010 Address Settings
DIP Switch
Data Bus Address
102***
103**
104**
105*
106*
107*
108*
Table 4.5: DX2010 DIP Switch Settings
* AMAX 3000 BE / 4000
2015.05 | 06 | F.01U.309.277
S1
S2
32
16
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Installation Manual
Zones
9 - 16
17 - 24
25 - 32
33 - 40
41 - 48
49 - 56
57 - 64
S3
S4
8
4
Off
Off
Off
Off
Off
Off
Off
On
Off
On
Off
On
Off
On
Bosch Sicherheitssysteme GmbH
AMAX panel
S5
S6
2
1
Off
On
On
Off
On
On
Off
Off
Off
On
On
Off
On
On