en | Settings
The output is reset in the following cases:
35 – Follow Zone
This output imitates the zone state. The output is operated according to the corresponding
zone.
The output is reset according to the corresponding zone.
36 - Schedule
This output is operated when a schedule is enabled.
The output is reset when the schedule is reset or the output time ends.
Output Mode
Three different output modes are available.
0 - Continuous output
The output is continuous, the level is high.
1 - Pulse output
The output occurs in pulses, the period is 1 second.
2- Continuous inverted output
The output is continuous, the level is low (level is high in idle state). When PO-1 or PO-2 is set
to inverted, supervision is disabled for these outputs.
Output Time
Each output is operated for a specific time and resets at the end of output time.
The actual output time of system audio alarm, system alarm, and follow zone event is related
to the ringing of the alarm siren.
The possible output time value range is 0 – 999 seconds.
6.6.2

Sirens

Alarm Siren Ringing Time
The alarm siren ringing time is valid only when the keypad alarm tone is enabled. When an
audio alarm occurs in the system, the alarm siren begins to ring. After a valid arming /
disarming command, an alarm reset or after the alarm siren ringing duration ends, the alarm
siren stops ringing.
For programming of alarm time, refer to Output Programming, page 137.
Beep For Warning Devices
Enables / disables beep for warning devices when the system is armed, disarmed, or during
walk test.
Internal Siren Beep as Indication
Enables / disables internal siren beep as indication when the system is armed, disarmed, or
programming mode is entered.
Silence Warning Device When Disarmed
Enables / disables silence warning device when disarmed or by pressing any key.
2015.05 | 06 | F.01U.309.277
The battery of the RF repeater is low.
An AC power fault of the RF repeater occurs.
The RF power is normal and the system is reset.
The programmed output time ends.