Installation; System Power Up; System Status Indicator; Installer And User Code Commands - Bosch ICP-AMAX4-P2-EN Quick Start Manual

Amax panel 4000; amax panel 4000 en
Hide thumbs Also See for ICP-AMAX4-P2-EN:
Table of Contents

Advertisement

AMAX panel 4000 / AMAX panel 4000
EN
3

Installation

This system / product must be installed by a qualified installer / service person.
During installation and wiring, the control panel power source must be switched-off to prevent
equipment damage.
The User has to disconnect all Telecommunication Network Connectors before unplugging the
power adaptor
After the control panel wiring is completed, connect the AC power and backup batteries.
The power light on the keypad will light to show that AC power is connected.
Notice!
- Use only non spillable battery
- Battery must be recycled and disposed of properly
- When battery is not replaced correctly risk of fire explosion or burning
Notice!
The system must be installed and maintained by qualified installer / service person.
Bosch recommends testing the whole alarm system at least once a week.
Maintenance should be done by qualified installer / service person four times a year.
3.1

System Power Up

After the system is powered up, set date and time. Otherwise, the system prompts as fault.
After the system is powered up or reset, it resets to previous arming / disarming status.
To reduce false alarms caused by system power-up (or by power supply restoration after both
mains supply and AUX power supply fail), the system is designed to not perform zone test
within one minute after power-up.
3.2

System Status Indicator

The system status is indicated by the LED status indicator on the system main board.
Slow flash of red status indicator (repeating on and off with an interval of 1 second) indicates
normal system operation.
3.3

Installer and User Code Commands

The system supports programmable 4- to 6-digit Installer and User Code to execute the
following programming and operating commands.
The installer commands can be used only when all areas of the system are in disarming status
with no alarm activated and when installer access is enabled from user.
Notice!
No identical User Codes are allowed. User Codes are not permitted to be the same as
Installer codes.
Bosch Sicherheitssysteme GmbH
To switch off the Power Source, an easy accessible circuit breaker must be available.
The System / product must be connected to a socket-outlet with a protective earthing
contact
Quick Start Guide
Installation | en
7
2013.07 | 03 | F.01U.267.113