AMAX panel
** AMAX 3000 / 3000 BE / 4000
*** AMAX 3000
On
Figure 4.3: DX2010 DIP Switch Settings
Notice!
When the data bus address is changed, the module and the panel need to be re-powered to
enable the new address
4.3.3
Wiring
The following table and graphic show how to wire DX2010 to the option bus of the AMAX
panel.
Do not use twisted pair or shielded cables to connect DX2010 to the AMAX panel.
Power Supply
AMAX panel
AMAX panel (DX2010 out not
used)
External power supply
Table 4.6: Lengths of cable for DX2010
AMAX 3000 BE / 4000
Figure 4.4: Connecting DX2010 to the AMAX panel
4.3.4
Status Indicator
LED Condition
On
Bosch Sicherheitssysteme GmbH
Off
O
N
D I P
1
2
3
4
5
AMAX 2100 / 3000
Optional Modules and Peripheral Devices | en
6
Wire diameter of 0.8mm
30m
305m
305m
DX2010
Denotation
Trouble Condition:
–
Grounding Conductor is not connected or there is a
communication failure between the module and the AMAX
panel
–
No zones distributed
–
Module address setting error
Installation Manual
Wire diameter of 1.2mm
76m
610m
610m
DX2010
_
+
12V
2015.05 | 06 | F.01U.309.277
17