AMAX panel
01 (as an
example for the
following zone
functions 02 to
15)
Bosch Sicherheitssysteme GmbH
Allow bypass/force arm (0 = disabled, 1 = allow
force alarm, 2 = allow bypass, 3 = allow both)
Silent alarm/chime mode (0 = disabled, 1 = silent
alarm, 2 = chime mode, 3 = both)
Pulse count (0 = disabled, 1 – 9 = 1 – 9 times)
Zone lockout (0 = disabled, 1 = 1 time, 2 = 3
times, 3 = 6 times, 4 = alarm duration)
Zone DEOL (0 = disabled, 1 = DEOL, 3 = NC, 4 =
NO) (3 and 4 are not applicable for wireless
zones)
Report (1 = receiver 1,
2 = receiver 2,
3 = receiver 3,
4 = receiver 4,
5 = receiver 1, 2, 3, 4,
6 = receiver 1 (2, 3, 4 backup)
7 = receiver 1 (2 backup) and receiver 3 (4
backup))
Cross zone/unverified alarm (0 = disabled, 1 =
unverified alarm, 2 = cross zone, 3 = both)
Domestic no. (1 = dom. 1,
2 = dom. 2,
3 = dom. 3,
4 = dom. 4,
5 = dom. 1, 2, 3, 4,
6 = dom. 1 (2, 3, 4 backup)
7 = dom. 1 (2 backup) and dom. 3 (4 backup)
8 = dom. 1, 2
9 = dom. 1 (2 backup)
10 = dom. 3, 4
11 = dom. 3 (4 Backup))
Zone reaction time (unit: x100ms)
Selection of a zone type*
Allow bypass/force arm
Silent alarm/chime mode
Pulse count
Zone lockout
Zone DEOL
Report
Installation Manual
Address Programming | en
1002
3
VDS-A
EN=0/2
1003
0
VDS-A
EN=0/2
1004
0
VDS-A EN=0
1005
3
1006
1
1007
6
VDS-A
EN=1/5/6/7
1008
0
VDS-A EN=0
1009
0
1010 – 1013
0003
1015 – 1016
01
1017
3
VDS-A
EN=0/2
1018
0
VDS-A
EN=0/2
1019
0
VDS-A EN=0
1020
3
1021
1
1022
6
VDS-A
EN=1/5/6/7
2015.05 | 06 | F.01U.309.277
129