en | Settings
RPC Arming
Sends perimeter arming report when the remote PC is used to arm areas through network or
telephone connection.
System Status Reporting
External Module Fault Report
Auxiliary Power Fault Report
When the system detects auxiliary power fault, the report will be sent.
Auxiliary Power Fault Restore Report
When the system detects auxiliary power fault recovery, the report will be sent.
AC Power Fault Report
When the system detects disconnection of AC power and after the AC fault delay time has
ended, the report will be sent.
AC Power Fault Recovery Report
When the system detects a recovery of the AC power that lasts longer than the AC power
delay report time, the report will be sent.
Battery Low Voltage Fault Report
When the battery voltage is lower than 11.0V or battery low voltage is detected in the dynamic
battery test, the AMAX panel will send the battery low voltage report.
The system continuously monitors the battery voltage and will perform a dynamic battery test
each time the system is armed, when the system is reset or in every battery check interval.
Battery Low Voltage Fault Recovery Report
When the battery voltage is lower than 12.0V or recovery to normal voltage is detected in the
dynamic battery test, the battery low voltage fault recovery report will be sent.
Times of Wrong Code Entry Exceeding Limit
When the times of entering wrong code reaches a specific value, an access denial report will
be generated and alarm will be made.
This function is used to prevent unwanted users from accessing the system. When the number
of incorrectly entered codes reaches a specific value, the AMAX panel will execute following
actions:
On-board Output 1 – 2 Fault
2015.05 | 06 | F.01U.309.277
System tamper report: In case of case tamper event, the system tamper report will be
sent. When case tamper recovers, a tamper recovery report will be sent
Zone Expansion Module Fault: When zone expansion module 1 – 6 fails, the report will be
sent. After the fault is recovered, the recovery report will be sent
Output Expansion Module Fault: When output expansion module 1 or 2 fails, the report
will be sent. After the fault is recovered, the recovery report will be sent
Network Module Fault: When network module 1 or 2 fails, the report will be sent. After
the fault is recovered, the recovery report will be sent
Keypad Fault: When fault occurs between the keypad and the AMAX panel, the report will
be sent. After the fault is recovered, the recovery report will be sent
Zone Expansion Module Tamper: When tamper occurs in the zone expansion module, the
tamper report will be sent. After the tamper recovers, a tamper recovery report will be
sent
Keypad Tamper: When tamper occurs in any keypads, the tamper report will be sent.
After the tamper recovers, a tamper recovery report will be sent
Activate alarm siren and other alarm outputs
Lock the keypad in which the incorrect codes have been entered for 3 minutes
Send an access denial report