Ring Times; Users And Codes; User Code - Bosch AMAX 2100 Installation Manual

Amax panel
Hide thumbs Also See for AMAX 2100:
Table of Contents

Advertisement

48
en | Settings
6.1.8

Ring Times

Ring Count
This function defines the number of rings before the AMAX panel answers an incoming call. It
is necessary to enable remote arming and remote upload/download to use this function.
The following values are selectable:
6.2

Users and Codes

The AMAX system provides two types of access codes, the installer codes and user codes.
Each of them allows specific access and operation of the AMAX panel functions.
6.2.1

User Code

The default users are master user 1 (code: [2580]) and master user 2 (code: [2581]). These
codes should be changed to individual codes. If a new user is assigned, an individual user
code is assigned to this user.
Notice!
Identical codes are not allowed. User codes are not permitted to be the same as the installer
code.
User Code Priority
User codes can differ in permission levels. Each user code is assigned to a permission level.
Code Permission Level
00
01
02
03
04
05
06 -15
Please refer to Installer Code, page 49 for a description of the user permission levels.
User Code in Area
This option has a different function dependant on which user type has been selected above.
2015.05 | 06 | F.01U.309.277
0 = The panel does not answer any incoming calls.
1 – 13 = Number of rings until the control panel answers.
14 = The control panel is called, the phone is allowed to ring only twice and hangs up.
After 8 seconds the control panel is called again and answers to the first ring.
15 = The control panel is called and the phone is allowed to ring only four times.
For Super User, Basic User, Arming User and Duress User:
For each of these user types any area can be assigned individually. Keyfobs are
automatically assigned to the selected areas as well.
For example: If 01 and 02 is selected in this option, area 01 and 02 is assigned. Keyfobs
are also assigned to area 01 and 02.
User Type
Master User 1
Master User 2
Super User
Basic User
Arming User
Duress User
No Priority
Installation Manual
AMAX panel
Bosch Sicherheitssysteme GmbH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amax 3000Amax 4000

Table of Contents