AMAX panel
Condition:
An onboard output is in a short circuit or open circuit condition.
Restore:
4
Supervise:
1.
2.
P
4 -Keypad Failure
Condition:
No communication between the panel and a keypad.
Restore:
4
Supervise:
1.
2.
P
5- System Failure
Condition:
Date and time is not set after the system is powered on.
Restore:
4
Supervise:
1.
2.
3.
6 - Communication Failure
Condition:
The panel can not send the report to the destination 1 after four attempts.
Restore:
Make sure that reports can be sent and reset the fault. For more information refer to System
Setting, page 71.
Bosch Sicherheitssysteme GmbH
Restore the onboard output to a normal condition and reset the fault. For more
information refer to Outputs, page 75.
Report the onboard output 1-2 fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
When the fault is reset, send the restored report to the configured destinations.
The FAULT indicator is turned off when there is no other system fault.
Keypad 1-16 failure
Restore the communication between the panel and the keypad and reset the fault. For
more information refer to Keypad Area, page 69.
Report the keypad fault to the configured destination programmed on address 124.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
When the fault is reset, send the restored report to the configured destinations.
The FAULT indicator is turned off when there is no other system fault.
Date and Time not set
Program date and time and reset the fault. For more information refer to System Setting,
page 71.
Report the date and time fault to the configured destination programmed on location
124.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description)
No report to the AMAX panel system, when date and time setting is recorded in
nonvolatile memory and AMAX Panel is reset. The FAULT indicator is turned off when
there is no other system fault.
Communication Fault 1 - 4
Installation Manual
Troubleshooting | en
153
2015.05 | 06 | F.01U.309.277