Front Panel - Extreme Networks BlackDiamond 8810 Hardware Installation Manual

Extreme blackdiamond 8810: installation guide
Hide thumbs Also See for BlackDiamond 8810:
Table of Contents

Advertisement

Extreme Networks 700/1200 W AC Power Supply Units

Front Panel

The front panel of the 700/1200 W AC PSU provides status LEDs.
on the front panel.
Table 11: 700/1200 W AC PSU front panel LED behavior
LED
Color
Power
Blinking Green
Solid Green
Off
Predictive
Blinking Amber
Failure
Off
Fails
Blinking Amber
Solid Amber
Off
The front panel on each 700/1200 W AC PSU contains two cooling fans as shown in
enters from the front vents on the 700/1200 W AC PSU and exits to the rear vents of the chassis.
Airflow through the 700/1200 W AC PSU is independent from the airflow that exists through the rest of
the chassis.
Figure 14: Cooling fans in the 700/1200 W AC PSU
The AC input is located on the front of the chassis directly in back of each power supply bay. The front
of the 700/1200 W AC PSU has a handle with a cam lever mechanism for both insertion and removal as
shown in
Figure
15.
Extreme Networks Consolidated XOS Hardware Installation Guide
Indicates
Power is present and standby output is on
AC power is present and power supply is operating normally
There is no power present
A fan has slowed down and is about to fail
The fans and power supply are operating normally
There is a current limit on 48 VDC output
The power supply has failed, or there is no AC power to this power supply
The power supply is operating normally
Open
Lock
Table 11
describes the LED behavior
Figure
14. Airflow
EX_015
52