Power Supply Cords; Fuse; Operating Conditions - Extreme Networks BlackDiamond 8810 Hardware Installation Manual

Extreme blackdiamond 8810: installation guide
Hide thumbs Also See for BlackDiamond 8810:
Table of Contents

Advertisement

Extreme Networks 700/1200 W AC Power Supply Units

Power Supply Cords

700/1200 W AC PSU(s) come with both 110 V AC and 220 V AC power supply cords. The 110 V AC
power supply cord allows for a maximum DC output power of 700 W. The 220V AC power supply cord
allows for a maximum DC output power of 1200 W.
All power supply cords provided by Extreme Networks are designed for use in the United States and
Canada only. Power supply cords for use outside of United States and Canada are typically provided by
a third party distribution center and must meet the following requirements:
Power supply cords must be agency certified for country of use.
Power supply cords must contain an IEC 320 C13 connector on the end of the PSU.
Power supply cords must contain an appropriate rated and approved wall plug applicable to the
country of installation.
Power supply cords must be more than 5m long.
Wire size must be a minimum of 16 AWG (1.0 mm
WARNING!
Ensure that the source outlet is properly grounded before plugging the AC supply power cord into a PSU.

Fuse

The 700/1200 W AC PSU line and neutral legs are both fused. Power to the chassis may still be live if
the neutral fuse is open. This is not a field operator replaceable fuse! In the event of failure, immediately
return the PSU for a complete replacement.
WARNING!
Trained and qualified service personnel must not attempt to configure or replace fuses within the 700/1200 W AC
PSUs! In the event of failure, immediately return the defective PSU for a complete replacement.

Operating Conditions

Operating conditions for the 700/1200 W AC PSU(s) are as follows:
Operating Temperature: 0°C to 40°C
Storage Temperature: -40°C to 70°C
Operating Humidity: 10% to 95% relative humidity, non-condensing
Operational Shock: 30 m/s
Extreme Networks Consolidated XOS Hardware Installation Guide
2
2
(3 g)
) copper stranded.
56

Hide quick links:

Advertisement

Table of Contents
loading