5.
To enable Barge In, dial
To disable Barge In, dial
6.
Press
Part II: Assign the Class of Service with Barge In Enabled to the Extension
1.
Enter the programming mode. You see:
USER: nnn
ENTER PROGRAM?
2.
Enter
1801:EXTENSION PROG
STATION#?
3.
Enter the number of the extension you want to program (e.g., 300) +
1801:STA:nnn
PT TYP?n:nnnnnn nnn
4.
Press
1801:STA:nnn
CLASS OF SERVICE?n
5.
Enter the Class of Service (1-15) you want to assign to the extension selected +
1801:STA:nnn
CLASS OF SERVICE?n
6.
Press
Press
Feature Quick Steps
To Barge-In on a call:
1.
Call busy extension or access busy trunk + Dial 4.
2.
Join the conversation in progress.

Call Waiting / Camp-On

Call Waiting helps busy extension users know when they have additional waiting calls. It also
lets callers wait in line for a busy extension without being forgotten.
With Call Waiting, an extension user may call a busy extension and wait in line (Camp-On) without hanging
up. When the user Camps-On (by dialing 2), the system signals the busy extension with two beeps indicating
the first waiting call. (The busy extension can be on a handset or Handsfree call.) The call goes through when
the extension becomes free. If an extension has more than one caller waiting, they queue on a first-in/first-
out basis (FIFO). The extension will not hear Camp-On beeps for additional waiting calls. Call Waiting /
Camp-On is enabled by default.
Programming
There are 3 steps to setting up Call Waiting / Camp-On:
Part I: Enable/disable Camp-On system-wide.
Part II: Enable/disable an extension's ability to Camp-On to a busy extension in Class of Service.
Part III: Assign the Class of Service with Camp-On enabled to the extension.
Part I: Enable/Disable Camp-On System-Wide
1.
Enter the programming mode. You see:
USER: nnn
ENTER PROGRAM?
2.
Enter
0201:TENANT OPTIONS
CALL WAIT?nnn
DS1000/2000 Quick Setup Guide
9
(for yes).
OR
6
(for no).
CONF
twice to exit program 0101.
1801
+
HOLD
. You see:
Vol Up
until you see:
CONF
and go back to step 3 to select another extension.
OR
CONF
twice to exit program 1801.
0201
+
HOLD
. You see:
Section 2: Customizing Features
Section 2: Customizing Features
HOLD
. You see:
HOLD
. You see: