Flash - NEC DS1000 Quick Setup Manual

Hide thumbs Also See for DS1000:
Table of Contents

Advertisement

To activate the relay for each Door Box:
1.
Enter the programming mode. You see:
USER: nnn
ENTER PROGRAM?
2.
Enter
1801:EXTENSION PROG
STATION #?nnn
3.
Enter the extension number of the Door Box you want to program +
1801:STA:nnn
PT TYP?10:DOOR BOX
4.
Press
1801:STA:nnn
RELAY OWNER?nnnn
5.
DS1000
If the Analog Door Box you are programming is connected to DOOR1, dial
If the Analog Door Box you are programming is connected to DOOR2, dial
DS2000
To assign the CPRU PCB relay to the Door Box, dial
6.
Press
Press
Feature Quick Steps
To place a call to the Door Box:
To answer the Door Box chimes from a keyset:
To control the system relay which in turn controls the door strike.

Flash

Extension users can access certain CO and PBX features (such as the telephone company's Call
Waiting) by interrupting trunk loop current.
Flash allows an extension user to access certain telephone company and PBX features by interrupting trunk
loop current. Flash lets an extension user take full advantage of whatever features the connected telco or
PBX offers. You must set the Flash parameters for compatibility with the connected telephone company or
PBX. By default, the Flash interval is 800 mS (.8 seconds).
Programming
To change the Flash interval:
1.
Enter the programming mode. You see:
USER: nnn
ENTER PROGRAM?
2.
Enter
0402:TRUNK TIMERS
CAMP-ON?nn
3.
Press
0402:TRUNK TIMERS
FLASH PBX
DS1000/2000 Quick Setup Guide
1801
+
HOLD
. You see:
Vol Up
until you see:
OR
CONF
to go back to step 2 and select another Door Box.
OR
CONF
twice to exit program 1801.
Lift handset and press
ICM
Lift handset or press
SPK
To open the relay, press
FLASH
To close the relay, Press
FLASH
0402
+
HOLD
. You see:
Vol Up
until you see:
Section 2: Customizing Features
1
+
CONF
+ Dial the Door Box extension number.
.
key or
OPEN
soft key.
key or
CLOSE
soft key.
Section 2: Customizing Features
HOLD
. You see:
1
+
CONF
.
2
+
CONF
.
.
2
2-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds2000

Table of Contents