2
User Guide V
IU 6400-S Converged Network Appliance
7 - 16
2. In the System menu, select Services Configuration.
3. Scroll to Enable Remote System Logging, and check the box.
4. Enter information as described in the following table:
Field
Remote Syslog Host:
Local Hostname:
Enable MOS Scoring:
MOS Threshold:
5. Press Submit.
Description
The address of the system running a
system log server. By default, the system
sends to port 514. The system log port
can be set by adding a colon and the port
number to the end of the address: e.g.
ADDRESS[:PORT]
Set the hostname for this system. By
default, the hostname is the system type.
Enable MOS scoring for media that is
passing through the 6400-S. Disabling
MOS scoring will improve system
performance. By default, MOS scoring is
Enabled.
Set the minimum allowable MOS for the
system. MOS values below this value will
cause system messages to be sent to the
system log. By default, the value is 2.5