RS-422 Connection (Multiple FINGER007 Connections)
RS422/RS232 converter is required to use RS422 communication between multiple FINGER0
07s and the PC. Please follow the following instructions.
1. First, you have to connect all RS422 port of all FINGER007s in parallel.
I. Connect RS422-TX (+) of one FINGER007 to RS422-TX (+) of another FINGER007.
II. Connect RS422-TX (-) of one FINGER007 to RS422-TX (-) of another FINGER007.
III. Connect RS422-RX (+) of one FINGER007 to RS422-RX (+) of another FINGER007.
IV. Connect RS422-RX (-) of one FINGER007 to RS422-RX (-) of another FINGER007.
2. Second, you have to connect one of RS422 port of FINGER007 to RS422/RS232 conver
ter.
I. Connect RS422-TX (+) of the one FINGER007 to RX (+) port of the converter.
II. Connect RS422-TX (-) of the one FINGER007 to RX (-) port of the converter.
III. Connect RS422-RX (+) of the one FINGER007 to TX (+) port of the converter.
IV. Connect RS422-RX (-) of the one FINGER007 to TX (-) port of the converter.
3. Plug in the RS232 9PIN connector of the converter to the COM1 or COM2 port of the P
C.
4. Install and run FINGER007 Application Software.
3

TCP/IP Communication Port Connection

Optional TCP/IP module is required to use TCP/IP communication between the FINGER007 a
nd the PC. Please follow the following instructions.
1. Connect the LAN cable of the network system to the RJ45 jack of the FINGER007.
2. Set the ID of the FINGER007.
3. Install and run the FINGER007Application Software.
TCP/IP Communication Port Connection
p.34