be denied with a time schedule error.
Operating Time Limit for Output Ports
If you assign a time schedule code to an output code, the Output Port generates con
stant output signals during the set time. (This feature can be used, for example, to ke
ep a door open during a certain period of time.)
Operating Time for Authentication Modes
Using this feature, you can have the FINGER007 change. It's Authentication Mode dur
ing a set time period. For example, if you set the FINGER007 to the RF + FP (P/W) mo
de and apply a time schedule code for the Authentication Mode, the FINGER007 will
operate in the RF-Only mode (Using RF Card verification alone) during the set time an
d shift into the RF + FP (P/W) mode (Using both RF Card and fingerprint verification)
out of the set time.
Holiday Schedule Setup
Excepting Sunday, you can program 32 holidays to one Holiday Schedule. Each Holida
y Schedule is linked to one time schedule which has time code for holidays. So you ca
n program all holidays to Holiday Schedule and the time code for holidays is program
med to holiday time zone of time schedule.
Example:
A
Holiday Schedule 01 linked to Time Schedule 01,
Holiday Schedule 02 linked to Time Schedule 02.
B
Holiday Schedule 02 linked to Time Schedule 01,
Holiday Schedule 01 linked to Time Schedule 02.
Door Open Alarm & Forced Door Open Alarm
The FINGER007 can report the open status of the door if the door is not closed within
a certain length of time (default: 3 sec) after the door is opened following a normal a
ccess procedure. (If this is the case, an alarm signal can be sent to the output port an
d the alarm event will be saved in the event buffer so that it can be uploaded to the P
C when communication is established.) If the door contact sensor detects forced ope
ning of the door, the Forced Door Open Alarm can be generated.
Functions
p.14