CHAPTER 4: SOFTWARE
4.3.2
Firmware
upgrades
CAUTION
MM3 MOTOR MANAGER 3 – INSTRUCTION MANUAL
Enter the file name for the saved setpoints or select any of the
displayed file names to update them.
All MM3 Motor Manager 3 setpoint files should have the extension
MM3 Motor Manager 3 (for example, MOTOR4.MM3).
Click OK to proceed.
The EnerVista MM3 Setup software reads the entered setpoint values and saves
them in the selected file.
Prior to downloading new firmware to the MM3 Motor Manager 3, it is necessary to save
the current MM3 Motor Manager 3 setpoints to a file (see the previous section). Please save
the setpoints before continuing. The following procedure describes how to load new
firmware into the MM3 Motor Manager 3 flash memory.
Upgrading the relay firmware may cause relay operation to change! Print and save the
original setpoints to a file that can be reloaded into the relay before proceeding with
the firmware upgrade.
Select the Communications > Upgrade Firmware menu item.
This opens the Firmware Upload window shown below.
Figure 4-8: Upgrade Firmware Window
Enter the appropriate information for the unit being upgraded.
The communication port, slave address, and baud rate can all be
found in the
Figure 4-7: Saving Setpoint Files
S1 CONFIGURATION
USING ENERVISTA MM3 SETUP
COMMUNICATIONS
menu.
4–9