GE Multilin MM3 Motor Manager 3 Instruction Manual page 17

Hide thumbs Also See for Multilin MM3 Motor Manager 3:
Table of Contents

Advertisement

CHAPTER 1: INTRODUCTION
CAUTION
NOTE
MM3 MOTOR MANAGER 3 – INSTRUCTION MANUAL
OPERATION
Overvoltage category:......2
Insulation voltage:..............300 V
OPERATING TEMPERATURES
Cold: ..........................................IEC60068-2-1, 16h at -40°C
Dry Heat: .................................IEC60068-2-2, 16h at +85°C
HUMIDITY (NON CONDENSING)
.....................................................IEC60068-2-30, 95% variant 1, 6 days
IP class: ....................................IEC 529 – IpX0
Fuse:..........................................0.5 A, 250 V fast blow, high breaking capacity
DIMENSIONS
Weight: ...................................6 lbs. 12 oz. (3.1 kg) maximum
Shipping box:................... 12" × 9" × 7.5" (350 mm × 229 mm × 190 mm)
INSTALLATION
Ventilation requirements:None
Cleaning requirements: None
HAZARD may result if the product is not used for its intended purpose.
It is recommended that all MM3 Motor Manager 3 relays are powered up at least once per
year to avoid deterioration of electrolytic capacitors in the power supply.
TECHNICAL SPECIFICATIONS
1–9