GE Multilin MM3 Motor Manager 3 Instruction Manual page 172

Hide thumbs Also See for Multilin MM3 Motor Manager 3:
Table of Contents

Advertisement

MODBUS MEMORY MAP
8–28
Table 8–2: Modbus Memory Map (Sheet 13 of 28)
Modicon
Address
dec.
hex
44271
4270
10AE
Local isolator
44272
4271
10AF
Auto permissive indication
Process interlock A name (read/write setpoints)
44273
4272
10B0
Interlock A name
characters 1 and 2
44274
4273
10B1
Interlock A name
characters 3 and 4
44275
4274
10B2
Interlock A name
characters 5 and 6
44276
4275
10B3
Interlock A name
characters 7 and 8
44277
4276
10B4
Interlock A name
characters 9 and 10
44278
4277
10B5
Interlock A name
characters 11 and 12
44279
4278
10B6
Interlock A name
characters 13 and 14
44280
4279
10B7
Interlock A name
characters 15 and 16
44281
4280
10B8
Interlock A name
characters 17 and 18
44282
4281
10B9
Interlock A name
characters 19 and 20
Programmable inputs (read/write setpoints)
44283
4282
10BA
Serial permissive
44284
4283
10BB
Start block alarm
44285
4284
10BC
Command mode change
when running
44286
4285
10BD
...Reserved...
44287
4286
10BE
...Reserved...
44288
4287
10BF
...Reserved...
Process interlock B name (read/write setpoints)
44289
4288
10C0
Interlock B name
characters 1 and 2
44290
4289
10C1
Interlock B name
characters 3 and 4
44291
4290
10C2
Interlock B name
characters 5 and 6
44292
4291
10C3
Interlock B name
characters 7 and 8
44293
4292
10C4
Interlock B name
characters 9 and 10
44294
4293
10C5
Interlock B name
characters 11 and 12
44295
4294
10C6
Interlock B name
characters 13 and 14
* – Maximum setpoint value and 65535 represent OFF; ** – 1/phase current scale factor × A; *** – 101
represents unlimited;
† – Minimum setpoint value represents OFF; ~ – 0.1 × A when high resolution mode is disabled;
0.01 × A when enabled
Description
Range
0 to 1
0 to 1
32 to
127
32 to
127
32 to
127
32 to
127
32 to
127
32 to
127
32 to
127
32 to
127
32 to
127
32 to
127
0 to 1
0 to 1
0 to 1
...
...
...
32 to
127
32 to
127
32 to
127
32 to
127
32 to
127
32 to
127
32 to
127
MM3 MOTOR MANAGER 3 – INSTRUCTION MANUAL
CHAPTER 8: COMMUNICATIONS
Step
Units
Format
Default
1
---
F14
0 =
DISABLE
1
---
F16
0 =
MANUAL
1
ASCII
F10
"PR"
1
ASCII
F10
"OC"
1
ASCII
F10
"ES"
1
ASCII
F10
"S "
1
ASCII
F10
"IN"
1
ASCII
F10
"TE"
1
ASCII
F10
"RL"
1
ASCII
F10
"OC"
1
ASCII
F10
"K "
1
ASCII
F10
"A "
1
---
F14
0 =
DISABLE
1
---
F14
0 =
DISABLE
1
---
F14
0 =
DISABLE
...
...
...
...
...
...
...
...
...
1
ASCII
F10
"PR"
1
ASCII
F10
"OC"
1
ASCII
F10
"ES"
1
ASCII
F10
"S "
1
ASCII
F10
"IN"
1
ASCII
F10
"TE"
1
ASCII
F10
"RL"
...
...
...

Advertisement

Table of Contents
loading

Table of Contents