ESTABLISHING THE BRIDGE CONNECTION
This section describes how to setup and establish the physical bridge
connection between the TRBMIM-T Station port and a lobe port on
another ring. See the TRBMIM/TRBMIM-T Local Management User's
Guide for information on configuring source-route bridging parameters.

4.1 SETTING UP THE STATION PORT

You setup the TRBMIM-T Station port by installing a properly configured
TPIM into the Station receptacle. This section describes how to configure
TPIMs for Station-port application and install them into the TRBMIM-T
Station receptacle. See Appendix A for information about TPIM
operational and media specifications.
Follow anti-static guidelines when unpacking and working with
!
TPIMs. Wear a properly grounded anti-static wriststrap and
avoid unnecessary handling of components.
C AUT IO N
4.1.1 Configuring TPIMs
TPIMs (see Figure 4-1) are shipped pre-configured to support
Ring In/Ring Out (RI/RO) application. For use in the TRBMIM-T,
however, you must configure the dip switches on the TPIMs to support
Station-port application.
TPIM-F2/F3
CHAPTER 4
TPIM-T2/T4
Figure 4-1 TPIMs
TPIM-T1
4-1