3.3.1 Tabletop or Shelf Installation

The following two subsections provide guidelines for installation on a
tabletop or shelf.
Guidelines for Tabletop and Shelf Installations
Tabletop and shelf installations must be within reach of the network
cabling and meet the requirements listed below:
A single phase 120 Vac, 15 A, grounded power receptacle must be
located within seven feet of the location.
In a shelf installation, the shelf must be able to support 30 pounds of
static weight for each device in the stack.
A temperature of between 5 C (41 F) and 50 C (122 F) must be
maintained at the installation site with fluctuations of less than 10 C
per hour.
For a tabletop or shelf installation, locate the SEHI within seven feet of its
power source and with an unrestricted free surface area as shown in
Figure 3-2.
18 IN.
6 IN.
If the installation requires that the SEHI is to be stacked, proceed to
Section 3.3.5. Otherwise, continue by connecting power as described in
Section 3.4.