The two methods of accessing a new module are:
access through a PC using a terminal application
access by Telneting to the module using the initial default IP address
Once you have used one of the two methods to access to the module, you should:
establish an administration session with the module
assign the module's new IP address
For more detailed instructions, refer to the sections below.
I
A
U
NITIAL
SSESS
SING A
Connect one end of the supplied null modem cable to the RS232 console port on the module, and
the other end of the cable to the communication port on the PC. On the PC you must then execute
a communication package to emulate a terminal (VT100).
Use the following default values for your communication package:
Baud rate
Parity
Data bits
Stop bits
Duplex
After you have connection to the module, you will be ready to
I
A
U
T
NITIAL
CCESS
SING
ELNET
You can use a remote device to Telnet into module using the module's initial default IP address
(192.186.254.254). The remote device can be a device with Telnet client software such as a PC or a
UNIX workstation, or it can be a second module or a Cabletron CyberSWITCH. Note that the
modules and CyberSWITCH systems have built-in Telnet client software.
If a CyberSWITCH or second module is acting as the Telnet client, simply enter the following
console command to Telnet into the module:
telnet < 192.186.254.254 >
If a remote device other than a Cabletron product is acting as the Telnet client, use the device's
Telnet application to connect to the initial default IP address.
After you make a Telnet connection you will be ready to establish an administration session (refer
to the following section for instructions).
E
A
STABLISHING AN
DMINISTRATION
Once you have connected to the module using either a terminal application or Telnet, you will be
prompted for a login ID and the initial password. Enter admin for both.
12
SmartSwitch Remote Access Module
ODULE
PC
T
A
AND A
ERMINAL
PPLICATION
9600
None
8
1
Full
S
ESSION
establish an administration