Assembling Feeders; Assembling The Straight Male Coaxial N Connector And The 1/2'' Feeder - Huawei AP7052DN Hardware Installation And Maintenance Manual

Table of Contents

Advertisement

AP7052DN&AP7152DN
Hardware Installation and Maintenance Guide
Table 5-13 PoE standard requirements for network cable quality
Standard
802.3af
802.3at
If an AP is connected to a switch or AC (excluding ACU2), you can run the virtual-cable-test
command on the switch or AC to check network cable connectivity. For details, see the
virtual-cable-test command in the command reference.

5.1.4 Assembling Feeders

5.1.4.1 Assembling the Straight Male Coaxial N Connector and the 1/2''
Feeder
Context
Figure 5-89 shows the components of an N coaxial connector and a 1/2" feeder cable.
Figure 5-89 Components of an N coaxial connector and a 1/2" feeder cable
A. Body of
connector
E. Cable jacket
Issue 01 (2017-12-29)
Connect multimeter probes to two ends of each wire in a network cable and check the
resistance value on the multimeter.
Connect a network cable to an AP. Use a multimeter to test the resistance between pins 1
and 2 (or between pins 3 and 6, 4 and 5, or 7 and 8) on the other end of the cable. The
cable's DC resistance approximately equals a half of the displayed value.
B. Back shell of
connector
F. Outer conductor of
feeder cable
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Maximum PD power consumption <
12.95 W
Maximum PD power consumption <
25.5 W
C. O-ring seal
G. Inner conductor of
feeder cable
5 Appendix
Total
Resistance of
a Network
Cable
≤ 20 ohms
≤ 20 ohms
≤ 12.5 ohms
D. Heat-shrink tubing
H. Insulation layer of
feeder cable
85