Filters do not affect the operation of the Alarm Database, merely which
parts of it you see. All alarms remain in the database, even if they are
filtered and not visible in a window. Incoming alarms continue to be
added to the database and displayed in the Unacknowledged Alarms
window, regardless of filter settings.
NB: When you close a window, any modified filter settings will be lost.
The following diagram shows which filters can be applied to each
window. A 'Custom Filter' represents a user-definable combination of
the Alarmed and Alarm type filters.
Alarm
Database

3.8.1 Generic / Device Filters

Many of the alarms PCNC processes can be generated by more than
one type of device. You may be interested in certain alarm types only if
they are sent by a particular device. For example, you may wish to see
a Connected alarm if it came from a KBU64, but not if it came from a
80-60100000-02
Custom Filter
only
Unacknowledged
Alarm Filter only
Device 1 Filter
+
Custom Filter
Device 2 Filter
+
Custom Filter
Figure 3.2 - PCNC Filtering
Alarms and Filters
Network Alarm
Log Window
Unacknowledged
Alarms Window
Device 1 Alarm
Log Window
Device 2 Alarm
Log Window
3–9