For example, the alert 00007- 2: ALERT Line inactive (Clock)
might look like this, once it has been imported into another program:
20/06/96
14:43:31
Each field is described in the following sections.
13.3.2.1 <Date> field
This is an 8 character text field. It is the date the alarm was generated,
in the form dd/mm/yy
13.3.2.2 <Time> field
This is an 8 character text field. It is the time the alarm was generated,
in the form hh:mm:ss. This time is in a 24-hour clock format.
13.3.2.3 <Unacknowledged flag> field
This is a single digit unsigned numeric field.
acknowledged, 1 if unacknowledged.
13.3.2.4 <Poll number> field
This is a 5 digit unsigned numeric field, and gives the Poll number of the
device which generated the alarm. This number is in the range 00000 to
99999.
13.3.2.5 <Channel number> field
This is a three digit unsigned numeric field which gives the channel
number on which the alert occurred. This number is in the range 000 to
999. By convention, Cabletron devices use channel numbers starting
at 1. A channel number of zero is used to indicate that the alarm applies
to the entire physical device, and not just to a single channel.