9.3 KBU 64
Polling needs to be turned on and the Poll number used must be the
same as the entry for that device in the Network Database.
To set up a KBU64 from the factory default settings, you need to type
the following commands:
SET POLL xxxxx
SET LOG ALERT
SET CONSOLE POLL
In the first command, xxxxx is the required poll number for the device.
When this is done, the KBU can send ALERTs to PCNC.
9.4 Cabletron Generic Shelf Products
To receive alarms in all Generic Shelf products, the GSMC must have
ALERTs enabled in the Command Port Menu (the default setting).
Every application card must also have ALERTs enabled in the Alarms
menu (this is also a default setting). All ALERTs will then be routed to
the GSMC command port for output to PCNC.
9.5 Other Cabletron Products
Polling needs to be enabled in each product and the Poll number used
must be the same as the entry for that device in the Network Database.
ALERTs must be enabled in the relevant menu of each product.