CBU-NM
User Manual
7.13.4 TrapTxOidPcnc=<Group object identifier>
Default:
1.3.6.1.4.1.233
Purpose:
Every SNMP trap contains an Object ID Number that
identifies the type of object from which it originated. The
TrapTxOidPcnc setting tells PCNC which OID to use when
generating traps to be forwarded to another copy of PCNC.
7.13.5 TrapTxOidNms=<Group object identifier>
Default:
1.3.6.1.4.1.233
Purpose:
Similar to the previous entry, this OID is used when
generating traps to be sent to an NMS.
7.13.6 TrapRxOid=<Group object identifier>
Default:
1.3.6.1.4.1.233
Purpose:
PCNC looks for this number in any incoming traps. If PCNC
receives a trap that does not start with this number, it will
discard the trap, regardless of its content.
7.13.7 NamesInTraps=<Boolean>
Default:
On
Purpose:
PCNC can include device names (as stored in the Network
Database) in SNMP traps if required. The NamesInTraps
entry controls whether or not it does so.