Figure 87
1. Cap
2. Filler neck (hydraulic-fluid
reservoir)
5.
Install the dipstick and cap onto the filler neck.
6.
Start the engine and use all the hydraulic
controls to distribute the hydraulic fluid
throughout the system.
7.
Check for leaks; then shut off the engine.
8.
Check the fluid level and add enough to raise
the level to Full mark on the dipstick.
Important:
Do not overfill the reservoir.
Changing the Hydraulic
Filter
Service Interval: Every 1,000 hours—If you
are using the recommended
hydraulic fluid, replace the
hydraulic filter.
Every 800 hours—If you are not using the
recommended hydraulic fluid or have ever
filled the reservoir with an alternative fluid,
replace the hydraulic filter.
WARNING
Hot hydraulic fluid can cause severe burns.
Allow the hydraulic fluid to cool before
performing any maintenance to the hydraulic
system.
Use a genuine Toro replacement filter (Part No.
86-3010).
Important:
Use of any other filter may void the
warranty on some components.
1.
Prepare the machine for maintenance; refer to
Preparing for Maintenance (page
2.
Clean around the filter mounting area. Place a
drain pan under the filter
the filter.
g341294
3. Dipstick
44).
(Figure
88) and remove
1. Hydraulic filter
3.
Lubricate the new filter gasket and fill the filter
with hydraulic fluid.
4.
Ensure that the filter mounting area is clean.
Screw the filter on until the gasket contacts the
mounting plate; then tighten the filter 1/2 turn.
5.
Start the engine and let it run for about 2 minutes
to purge air from the system. Shut off the engine
and check for leaks.
61